Fire Rated Roof Assemblies & Roof Covering Materials

Class A, B or C Roof Assembly per the International Building Code (IBC) - ASTM E-108, UL 790, FM 4470


CPI Daylighting

<
FIRE RATED ROOF ASSEMBLY Test Standards
QUADWALL FIRE RATED PANEL
<br />AMERICAN HEBREW ACADEMY <br />  Administration Building
METHODIST WILLOWBROOK HOSPITAL ATRIUM
Museum of Natural History
ELIHU HARRIS STATE OFFICE BUILDING ATRIUM
>
FIRE RATED ROOF ASSEMBLY Test Standards

The specially configured Quadwall® Fire Rated panel system passed all three test standards as required by the IBC and NFPA codes:

  1. Flame Spread Test
  2. Intermittent Flame Test 
  3. Burning Brand Test

The following results allowed this system to achieve a Class A Roof Assembly listing:

  • No portion of the Quadwall® panels were blown off or fell off the deck in the form of flaming or glowing brands
  • The roof deck was not exposed by breaking, sliding, cracking or warping of the glazing panels
  • No portion of the Quadwall® panel system fell away in the form of glowing particles
  • There was no sustained flaming of the underside of the panel system



Overcome Code Restrictions for Use of Light Transmitting Plastics with A Patented Fire Rated Translucent System 

The Quadwall® Fire Rated Roof Assembly has been listed and labeled by Approved Independent Agencies

for Class A, B or C Roof Assemblies & Roof Coverings, as required by the IBC Building Code.

 All standard Quadwall systems are rated as Class C Roof Coverings  -  Specially engineered Quadwall systems are rated as Class A or B Roof Coverings.

CPI Fire Rated Panel Systems provide ALL of the design flexibility and benefits of CPI Daylighting's  Quadwall Translucent Panel Systems.